The new X-MET5000TXR has been developed specifically by Oxford Instruments for fast, lightweight and portable XRF analysis and RoHS compliance screening of heavy metals in plastics, solder materials and printed circuit boards.

Features include:

Quick quantitative analysis of all restricted elements: cadmium (Cd), lead (Pb), mercury (Hg), hexavalent chromium (Cr6+), polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE)
Portability allows you to bring the analyser to the test site
Sort Pb-free from Pb-containing components in seconds
Screen for Pb and Cd in plastic parts
Separate PVC or Br containing plastics in seconds for plastic recycling
Sample size and form can vary extensively – anything from small components to large parts
Quick on-site quality control to analyze various other elements like Ag, Cu, Sb, Bi etc. from solder and Cl, Ti, Zn, Se etc. in plastics

ROHS

Shimadzu introduces its improved compact tabletop energy-dispersive X-ray fluorescence EDX-720 spectrometer

The EDX-720 is released with improved sensitivity for Lead (Pb) and Cadmium (Cd) which are most important elements for the environmental analysis of green product (see RoHS below). Furthermore, EDX-720 also has new attractive functions such as the auto-selection of suitable calibration curve (e.g. PE/PVC calibration curve), the auto-reduced measurement time or the report generator for the RoHS/WEEE analysis.

Analysis using X-rays
Energy Dispersive X-ray fluorescence spectrometer (EDX) is the instrument to perform qualitative and quantitative element analysis in the range from 6C/11Na to 92U and is the ideal tools for non-destructive applications. EDX is used in many different applications areas in the chemical, electronic and food industries as well as refineries. It can be used with solid, powder and liquid samples. This is achieved by applying X-ray to the sample and then analysing the re-emitted element characteristic fluorescent X-ray. Security functions effectively prevent exposure to X-rays at all times.

High flexibility

The large sample chamber accepts samples up to 300 mm diameter and 150 mm height. Additionally, many accessories are available, for instance a precision stage for accurate sample positioning as well as various sample turrets for 8 or 16 samples. The detector system requires liquid Nitrogen (N2) but a thermoelectric cooled detector system is also available. For the measurement of small samples, the X-ray is decreased easily using the two optional collimator assemblies. Two different assemblies are available:
1, 3, 5, 10 mm
0.3, 1, 3, 10 mm
The exact positioning of small samples can be monitored accurately using an optional colour CCD camera.

WEEE and RoHS
In addition, the EDX series offers, with respect to WEEE (Waste Electrical and Electronic Equipment) and RoHS (Restriction of the use of certain Hazardous Substances in electrical and electronic equipment) simple and fast decision-making criteria in order to adhere to these directives. The EDX systems enable analyses of mercury, cadmium and lead in polymer building parts (such as casings and cable solderings) down to the ppm range. During EDX analysis, hexavalent chromium, PBB (polybrominated biphenyls) and PBDE (polybrominated diphenyl ether) are detected as elemental chromium and elemental bromine.